Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.838
Filtrar
1.
Intensive Care Med Exp ; 12(1): 46, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38717558

RESUMO

BACKGROUND: Assessment of dynamic parameters to guide fluid administration is one of the mainstays of current resuscitation strategies. Each test has its own limitations, but passive leg raising (PLR) has emerged as one of the most versatile preload responsiveness tests. However, it requires real-time cardiac output (CO) measurement either through advanced monitoring devices, which are not routinely available, or echocardiography, which is not always feasible. Analysis of the hepatic vein Doppler waveform change, a simpler ultrasound-based assessment, during a dynamic test such as PLR could be useful in predicting preload responsiveness. The objective of this study was to assess the diagnostic accuracy of hepatic vein Doppler S and D-wave velocities during PLR as a predictor of preload responsiveness. METHODS: Prospective observational study conducted in two medical-surgical ICUs in Chile. Patients in circulatory failure and connected to controlled mechanical ventilation were included from August to December 2023. A baseline ultrasound assessment of cardiac function was performed. Then, simultaneously, ultrasound measurements of hepatic vein Doppler S and D waves and cardiac output by continuous pulse contour analysis device were performed during a PLR maneuver. RESULTS: Thirty-seven patients were analyzed. 63% of the patients were preload responsive defined by a 10% increase in CO after passive leg raising. A 20% increase in the maximum S wave velocity after PLR showed the best diagnostic accuracy with a sensitivity of 69.6% (49.1-84.4) and specificity of 92.8 (68.5-99.6) to detect preload responsiveness, with an area under curve of receiving operator characteristic (AUC-ROC) of 0.82 ± 0.07 (p = 0.001 vs. AUC-ROC of 0.5). D-wave velocities showed worse diagnostic accuracy. CONCLUSIONS: Hepatic vein Doppler assessment emerges as a novel complementary technique with adequate predictive capacity to identify preload responsiveness in patients in mechanical ventilation and circulatory failure. This technique could become valuable in scenarios of basic hemodynamic monitoring and when echocardiography is not feasible. Future studies should confirm these results.

2.
Theriogenology ; 224: 41-49, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38733813

RESUMO

This study evaluated the efficiency of a rapid reinsemination program allowing timed AI (TAI) every 21d (ReBreed21) in a commercial beef cow-calf operation. Nelore females from different parities (n = 2085) were synchronized for first TAI (D0 = TAI) using an estradiol/progesterone (E2/P4) protocol and assigned to one of three reinsemination programs: Resynch33 (n = 753), traditional resynch program with second TAI at D42 after first TAI; ReBreed21 (n = 687); or ReBreed21+EC (n = 670). The ReBreed females (n = 1357) received intravaginal P4 insert on D12, on D19 P4 was removed, and a dose of equine chorionic gonadotropin (eCG) was administered, then, ReBreed21 females received 0.6 mg of EC (ReBreed21+EC) or nothing (ReBreed21) and on D21, nonpregnancy (NP) was determined using Doppler ultrasound to detect corpus luteum (CL) blood flow (BF) (NP: <25 % BF pixels of total CL area) and NP cows received immediate TAI and GnRH to induce ovulation. Pregnancy diagnosis was performed at D33 after TAI following all TAIs. Cows considered pregnant at D21, based on CL BF, but NP on D33 were designated False-Positives (FP) and false negatives (FN) were number of nonpregnant cows/heifers on d21 based on the CL BF found to subsequently be pregnant on D33 divided by the total number pregnant. Pregnancy/AI (P/AI) did not differ for the first TAI (55.1 %) among the treatments. Heifers had similar P/AI at the second AI in all groups and similar to the first AI. Primiparous had greater P/AI in ReBreed21+EC and Resynch33 at s TAI compared to ReBreed21, 51.7 %, 55.8 %, 34.2 %, respectively. Multiparous had greater P/AI at second TAI in Resynch33 (60.9 %) than ReBreed21 programs (34.7 %). The percentage FP and FN among ReBreed21 programs did not differ, 13.8 and 0.2 %, respectively. Overall accumulative pregnancies on D21 of the breeding season were greater for ReBreed21 and ReBreed21+EC than Resynch33 (69.7 %, 71.6 %, and 55.5 %, respectively). However, on D42 of the breeding season, only heifers had greater pregnancies in ReBreed21 programs than Resynch33 (73.3 %, 74.3.6 %, and 63.2 %, respectively). Average days to pregnancy were less (P = 0.01) for ReBreed21 and ReBreed21+EC than Resynch33. Thus, the ReBreed21 strategy can improve the efficiency of TAI programs in beef cattle. Of interest, ReBreed21 was particularly effective in nulliparous, somewhat effective in primiparous when EC was added to the program, but relatively ineffective in multiparous beef cattle.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38697934

RESUMO

Color pulsed-wave Doppler ultrasound (CPWD-US) emerges as a pivotal tool in intensive care units (ICUs) for diagnosing acute kidney injury (AKI) swiftly and non-invasively. Its bedside accessibility allows for rapid assessments, making it a primary imaging modality for AKI characterization. Furthermore, CPWD-US serves as a guiding instrument for key diagnostic-interventional procedures such as renal needle biopsy and percutaneous nephrostomy, while also facilitating therapy response monitoring and AKI progression tracking. This review shifts focus towards the integration of renal ultrasound into ICU workflows, offering contemporary insights into its utilization through a diagnostic-standard-oriented approach. By presenting a flow chart, this review aims to provide practical guidance on the appropriate use of point-of-care ultrasound (POC-US) in critical care scenarios, enhancing diagnostic precision, patient management, and safety, albeit amidst a backdrop of limited evidence regarding long-term outcomes.

5.
J Ultrasound Med ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747480

RESUMO

OBJECTIVES: To detect ultrasonographic anatomical alterations in all the skin layers in patients with vitiligo. METHODS: A prospective observational color Doppler ultrasound study was performed in nonsegmental face and/or neck vitiligo patients without a history of previous treatments. Two sites, a lesional area and a contralateral clinically healthy region, were ultrasonographically studied and compared in the same patient. All cases were studied in high-frequency (24 MHz) and ultra-high-frequency (70 MHz) ultrasound devices with the highest axial spatial resolution available in the market. Demographic data of the sample, ultrasound grayscale, and color Doppler features were recorded and analyzed. RESULTS: Ten patients met the study criteria (60% females; mean age 49 years). All cases presented ultrasonographic undulation of the epidermis in the affected zones vs 50% in the healthy control regions, being more prominent in the vitiligo areas. Eighty percent demonstrated intense hypoechoic thin plaques in the upper dermis (subepidermal). All vitiligo areas presented thickening and hypoechogenicity of the regional hair follicles and/or pilosebaceous units. Ninety percent showed prominent sebaceous glands, and 20% demonstrated a hypoechoic cap surrounding the sebaceous glands in the lesional areas. Dermal hypervascularity was detected in 100% of the affected regions and 40% of the clinically healthy areas. CONCLUSION: Ultrasound can identify subclinical inflammatory cutaneous patterns in the epidermis, dermis, hair follicles, pilosebaceous units, and sebaceous glands in vitiligo. This noninvasive information can support early detection, monitoring, and research, including the clinical trials of drugs used to manage this devastating disease.

6.
Ultrasonics ; 141: 107332, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38718460

RESUMO

BACKGROUND: Stroke is the second leading cause of death across the globe. Early screening and risk detection could provide early intervention and possibly prevent its incidence. Imaging modalities, including 1D-Transcranial Doppler Ultrasound (1D-TCD) or Transcranial Color-code sonography (TCCS), could only provide low spatial resolution or 2D image information, respectively. Notably, 3D imaging modalities including CT have high radiation exposure, whereas MRI is expensive and cannot be adopted in patients with implanted devices. This study proposes an alternative imaging solution for reconstructing 3D Doppler ultrasound geared towards providing a screening tool for the 3D vessel structure of the brain. METHODS: The system comprises an ultrasound phased array attached to a servo motor, which can rotate 180˚ at a speed of 2˚/s. We extracted the color Doppler ROI from the image before reconstructing it into a 3D view using a customized pixel-based algorithm. Different vascular diameters, flow velocity, and depth were tested using a vascular phantom with a pumped flow to confirm the system for imaging blood flow. These variables were set to mimic the vessel diameter, flow speed, and depth of the Circle of Willis (CoW) during a transcranial screening. RESULTS AND CONCLUSIONS: The lower values of absolute error and ratio were found in the larger vascular channels, and vessel diameter overrepresentation was observed. Under different flow velocities, such diameter overrepresentation in the reconstructed flow did not change much; however, it did change with different depths. Meanwhile, the setting of the velocity scale and the color gain affected the dimension of reconstructed objectives. Moreover, we presented a 3D image of CoW from a subject to demonstrate its potential. The findings of this work can provide a good reference for further studies on the reconstruction of the CoW or other blood vessels using Doppler imaging.

7.
J Obstet Gynaecol India ; 74(2): 125-130, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38707875

RESUMO

Background: According to WHO, hypertensive disease is the leading cause of direct maternal mortality accounting for 10-25% in developing countries (James in Heart, 90(12):1499-504). This study compares the combinations of mean arterial pressure (MAP) and uterine artery doppler (UAD) versus serum-free ß HCG, pregnancy-associated plasma protein-A, and placental growth factor (PlGF) versus a combination of all variables at 11 to 13+6 as long-term predictors of pregnancy-induced hypertension (PIH). Materials and Methods: A prospective, observational cohort study recruited 97 primigravidae at 11 to 13+6 weeks gestation at GMCH. Follow-up was done at 32-34 weeks and before delivery. Development of PIH, mode of delivery, birthweight, maternal and fetal adverse outcomes were documented, analyzed and compared among three groups. In Group A-biophysical markers, Group B-biochemical markers and in Group C all variables were used. Results: The mean age, maternal weight, height and BMI of patients developing gestational hypertension were 30 ± 5 years, 64.3 ± 12.5 kg, 155.8 ± 5.5 cm and 26.4 ± 4.1, respectively. Out of the 3, Group C is the best screening test for predicting the overall chance of development of gestational hypertension with a sensitivity of 97.37% and specificity of 38.98% (p < 0.0001). A mild negative correlation is seen between PlGF levels and severity of PIH (p-0.0382). Conclusion: MAP and UAD can be easily incorporated into the infrastructure of most hospitals. If the biochemical test kits are made available at a low cost through available programs such as JSSK, it can bring down the MMR by preventing gestational hypertension.

8.
Crit Care Explor ; 6(5): e1083, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38694846

RESUMO

OBJECTIVES: This prospective cohort study aimed to investigate changes in intracranial pressure (ICP) and cerebral hemodynamics in infants with congenital heart disease undergoing the Glenn procedure, focusing on the relationship between superior vena cava pressure and estimated ICP. DESIGN: A single-center prospective cohort study. SETTING: The study was conducted in a cardiac center over 4 years (2019-2022). PATIENTS: Twenty-seven infants with congenital heart disease scheduled for the Glenn procedure were included in the study, and detailed patient demographics and primary diagnoses were recorded. INTERVENTIONS: Transcranial Doppler (TCD) ultrasound examinations were performed at three time points: baseline (preoperatively), postoperative while ventilated (within 24-48 hr), and at discharge. TCD parameters, blood pressure, and pulmonary artery pressure were measured. MEASUREMENTS AND MAIN RESULTS: TCD parameters included systolic flow velocity, diastolic flow velocity (dFV), mean flow velocity (mFV), pulsatility index (PI), and resistance index. Estimated ICP and cerebral perfusion pressure (CPP) were calculated using established formulas. There was a significant postoperative increase in estimated ICP from 11 mm Hg (interquartile range [IQR], 10-16 mm Hg) to 15 mm Hg (IQR, 12-21 mm Hg) postoperatively (p = 0.002) with a trend toward higher CPP from 22 mm Hg (IQR, 14-30 mm Hg) to 28 mm Hg (IQR, 22-38 mm Hg) postoperatively (p = 0.1). TCD indices reflected alterations in cerebral hemodynamics, including decreased dFV and mFV and increased PI. Intracranial hemodynamics while on positive airway pressure and after extubation were similar. CONCLUSIONS: Glenn procedure substantially increases estimated ICP while showing a trend toward higher CPP. These findings underscore the intricate interaction between venous pressure and cerebral hemodynamics in infants undergoing the Glenn procedure. They also highlight the remarkable complexity of cerebrovascular autoregulation in maintaining stable brain perfusion under these circumstances.


Assuntos
Circulação Cerebrovascular , Cardiopatias Congênitas , Hemodinâmica , Pressão Intracraniana , Ultrassonografia Doppler Transcraniana , Humanos , Lactente , Estudos Prospectivos , Feminino , Masculino , Pressão Intracraniana/fisiologia , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Ultrassonografia Doppler Transcraniana/métodos , Hemodinâmica/fisiologia , Estudos de Coortes , Técnica de Fontan , Veia Cava Superior/fisiopatologia , Veia Cava Superior/diagnóstico por imagem
9.
J Vasc Access ; : 11297298241250379, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708835

RESUMO

BACKGROUND: An accessible tool is required to analyze volume flow trends in arteriovenous fistulas for hemodialysis. Earlybird, an easy-to-place ultrasound Doppler device, has shown comparable accuracy to duplex ultrasound. In this study, we compared volume flow measurements obtained with duplex ultrasound and the dilution technique to an enhanced earlybird device, featuring a dual Doppler probe system, eliminating the requirement for a known insonation angle. METHODS: Nine patients with a distal radiocephalic arteriovenous fistula were monitored for 12 months with regular volume flow measurements. Correlation and inter- and intra-class reliability analyses were conducted. RESULTS: An overall moderate correlation was observed between earlybird and duplex ultrasound or dilution technique (intraclass correlation coefficient = 0.606 (95% confidence interval 0.064, 0.721) and 0.581 (0.039, 0.739), respectively). Duplex ultrasound compared to dilution measurements, demonstrated an overall moderate correlation (0.725 (0.219, 0.843)). Correlation between earlybird and duplex ultrasound was stronger for the arteriovenous fistula (0.778 (0.016, 0.901)) than the brachial artery (0.381 (-0.062, 0.461)). For earlybird, inter-rater reliability was excellent for the arteriovenous fistula (0.907 (0.423, 0.930)) and poor for the brachial artery (0.430 (0.241, 0.716)). Duplex ultrasound showed a good inter-rater reliability (arteriovenous fistula: 0.843 (0.610, 0.871), brachial artery: 0.819 (0.477, 0.864)). The overall intra-rater reliability was good for duplex ultrasound (rater A: 0.893 (0.727, 0.911); rater B: 0.853 (0.710, 0.891)), while excellent for earlybird (rater A: 0.905 (0.819, 0.928); rater B: 0.921 (0.632, 0.969)). CONCLUSION: We observed a weaker correlation in the measurements of volume flow rates in arteriovenous fistulas when obtained using earlybird compared to dilution technique, unlike the comparison between duplex ultrasound and the dilution technique. However, inter-rater reliability for the arteriovenous fistula was excellent with earlybird and good with duplex ultrasound, indicating the potential of earlybird as a tool for frequent measurements, enabling trend surveillance and predicting adverse outcomes.

10.
World Neurosurg X ; 23: 100377, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38698836

RESUMO

Objective: This study aimed to compare microvascular Doppler sonography (MDS) and laser speckle contrast imaging (LSCI) for assessing vessel patency and aneurysm occlusion during microsurgical clipping of intracranial aneurysms. Methods: MDS and LSCI were used after clip placement during six neurovascular procedures including six patients, and agreement between the two techniques was assessed. LSCI was performed in parallel or right after MDS evaluation. The Doppler response was assessed through listening while flow in the LSCI videos was evaluated by three blinded neurovascular surgeons after the surgery. Statistical analysis determined the agreement between the techniques in assessing flow in 18 regions of interest (ROIs). Results: Agreement between MDS and LSCI in assessing vessel patency was observed in 87 % of the ROIs. LSCI accurately identified flow in 93.3 % of assessable ROIs, with no false positive or negative measurements. Three ROIs were not assessable with LSCI due to motion artifacts or poor image quality. No complications were observed. Conclusions: LSCI demonstrated high agreement with MDS in assessing vessel patency during microsurgical clipping of intracranial aneurysms. It provided continuous, real-time, full-field imaging with high spatial resolution and temporal resolution. While MDS allowed evaluation of deep vascular regions, LSCI complemented it by offering unlimited assessment of surrounding vessels.

11.
Heliyon ; 10(9): e30003, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38699032

RESUMO

Objective: Cerebral hyperperfusion syndrome (CHS) is the most severe complication of carotid artery stenting (CAS) or endarterectomy (CEA). Staging treatment can effectively reduce the risk of CHS without increasing the risk of ischemic stroke. The first stage of balloon dilatation is critical for staged treatment. However, the successful criterion of the first stage balloon dilatation is still inconsistent. Method: In the current study presents a case of a 61-year-old male with bilateral internal carotid subtotal occlusion, transcranial doppler (TCD) was used to measure middle cerebral artery (MCA) flow rate on the narrow side of surgery and the results are promising. Result: Intraoperative TCD monitoring is expected to be an evaluation criterion for staged angioplasty for carotid artery stenosis. Conclusion: The approach of blood flow velocity in the brain based on intraoperative measurement of TCD during the treatment of this patient is a new idea for staging treatment in the future.

12.
Ceska Gynekol ; 89(2): 102-106, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38704221

RESUMO

MATERIALS AND METHODS: We conducted an analysis on 231 pregnant women. A proctologist examined the patients three times: in the 1st trimester (within the first 15 weeks), in the 3rd trimester (29-40 weeks), and 12 months after childbirth. RESULTS: The total number of fecal incontinence observations among women included in the study was 66 cases (28.6%), detected at the final visit. Risk factors for fecal incontinence with a high probability were age over 36 years (P = 0.001), low physical activity (P = 0.034), three or more pregnancies resulting in childbirth (P = 0.022), history of hemorrhoids (P = 0.027), perianal discomfort on the first visit (P = 0.045), and constipation on the first visit (P = 0.006). Factors such as being overweight, marital status, education, living conditions, living area, and infant size did not have significance for fecal incontinence. DISCUSSION: Pregnancy- and obstetric-related risk factors contributing to fecal incontinence are multifactorial, including factors such as multiple childbirths with trauma to the pelvic muscles or anal sphincter muscles, chronic constipation, age, and vaginal deliveries. However, currently, there is no clear concept for the prevention of fecal incontinence in pregnant women. CONCLUSION: The prevalence of fecal incontinence among pregnant women is 12.9%, which increases to 28.6% one year after childbirth. The most common complaint was involuntary passage of intestinal gas. Risk factors for fecal incontinence with a high probability included being over 36-years old, low physical activity, three or more pregnancies resulting in childbirth, a history of hemorrhoids, perianal discomfort, and constipation in the 1st trimester of pregnancy.


Assuntos
Incontinência Fecal , Complicações na Gravidez , Humanos , Feminino , Gravidez , Incontinência Fecal/epidemiologia , Incontinência Fecal/etiologia , Fatores de Risco , Adulto , Complicações na Gravidez/epidemiologia , Prevalência
13.
Wiad Lek ; 77(3): 462-471, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38691788

RESUMO

OBJECTIVE: Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol. PATIENTS AND METHODS: Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF). RESULTS: Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration. CONCLUSION: Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.


Assuntos
Carga Imediata em Implante Dentário , Humanos , Pessoa de Meia-Idade , Adulto , Masculino , Feminino , Contenções , Osseointegração , Implantes Dentários , Implantação Dentária Endóssea/métodos , Tomografia Computadorizada de Feixe Cônico
14.
Clin Neurol Neurosurg ; 241: 108289, 2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38692117

RESUMO

OBJECTIVE: Transcranial Doppler ultrasound (TDUS), computed tomography angiography (CTA), and transcranial Doppler ultrasound to detect cerebral blood flow are among the adjunctive tests in diagnosing brain death. This study aimed to investigate the effectiveness of orbital doppler ultrasound (ODUS). METHODS: This prospective, single-blind study included 66 patients for whom brain death was to be diagnosed. Primary outcome measures were ODUS measurements, Ophthalmic artery peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistive indices (RI) measurements recorded during the brain death determination process. Secondary outcome measures were computed tomography angio (CTA), transcranial Doppler ultrasound (TDUS), and demographic data. RESULTS: This study investigating the effectiveness of ODUS in diagnosing brain death provided diagnostic success with 100% sensitivity and 93% specificity compared to CT angiography. It was noted that anatomical variations may limit its use. CONCLUSION: ODUS was found to have high sensitivity and specificity in the diagnosis of clinical brain death. It may assist in early prognostic assessment and shorten patient follow-up and diagnostic processes.

15.
Ultrasound ; 32(2): 128-134, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38694826

RESUMO

Introduction: Undifferentiated sarcoma is considered a rare and aggressive type of soft tissue sarcoma with the lower extremity reported as the common site for soft tissue sarcomas. Case presentation: We present a rare incidental finding of undifferentiated sarcoma during lower limb Doppler ultrasound with a presenting symptom of right thrombotic-like calf pain in a 49-year-old female. Discussion: On ultrasound, the presented undifferentiated sarcoma appeared as a large heterogeneous, oval-shaped, soft tissue mass deeply seated in the right calf with involvement of the soleus muscle. The features on ultrasound mimicked those of a hematoma; however, the possibility of the lesion being a haematoma was promptly ruled out with the demonstration of internal vascularity on colour Doppler application. The case was then referred to a sarcoma triage multidisciplinary team for a review. Magnetic resonance imaging, computed tomography and biopsy were parts of the diagnostic workup for this case, histology confirmed the soft tissue lesion to be an undifferentiated sarcoma. Emergency above knee amputation of the right leg was performed as part of the patient's treatment. Conclusion: This case report presents a rare incidental finding of undifferentiated sarcoma encountered during lower limb Doppler ultrasound causing thrombotic-like calf pain. Sonographers are encouraged to pay necessary attention and carefully examine any adjacent and incidental soft tissue lesion during lower limb Doppler ultrasound using compression, two-dimensional imaging and colour imaging, especially those that appear with characteristic features of malignancy; urgent referral should be made of such cases to a tertiary soft tissue sarcoma centre for further evaluation and management.

16.
Res Pract Thromb Haemost ; 8(3): 102396, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38694839

RESUMO

Background: Plantar vein thrombosis (PVT) is a rare condition. Less than 50 cases have been described in the literature. Evidence from interventional and observational studies is sparse or lacking. Objectives: To describe a consecutive cohort of patients diagnosed with PVT at a single academic institution over the past 17 years. Methods: We searched medical charts from patients managed at the University Hospital Zurich between 2005 and 2022. PVT was detected through sonography (eg, in the presence of a noncompressible deep vein) and/or magnetic resonance (eg, a vein with a filling defect on non-contrast-enhanced or contrast-enhanced imaging). The study was approved by the local ethics commission. Results: We identified 45 patients who had been assessed for PVT. After manual check of these cases, we selected 16 patients with a confirmed, objective diagnosis. Median age was 62 (25th-75th percentiles, 46-73) years, and 9 (56%) patients were women. All patients were symptomatic, usually reporting local pain in the foot (100%) and swelling (67%). The most frequent risk factors were cancer (n = 6; 38%) and prior deep vein thrombosis (n = 4; 25%). Overall, 80% of patients received oral anticoagulation and 20% received parenteral anticoagulation for a median of 90 days. Over a median follow-up of 17 months, 2 (12.5%) recurrent venous thromboembolism events were recorded following the discontinuation of anticoagulation. Index vein recanalization occurred in all 15 survivors. One patient died from cancer 2 years after PVT diagnosis. Conclusion: We provided initial information on the clinical characteristics, treatment, and course of PVT, which partly resembles that of distal deep vein thrombosis.

17.
Insights Imaging ; 15(1): 113, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38734857

RESUMO

OBJECTIVE: To investigate the structural alterations, neovascularity, and elasticity of tendons and the relationship between elasticity and the Patient Rated Tennis Elbow Evaluation score after undergoing US-guided fenestration or surgery in patients with chronic lateral elbow tendinopathy. METHODS: Participants from the per-protocol population of a randomized trial conducted between October 2016 and June 2020 were included. The surgery and fenestration groups included 24 (mean age, 50 ± 7 years [standard deviation], 10 men) and 29 (47 ± 8 years, 18 men) participants, respectively. Ultrasound exams were performed at baseline, 6 months, and 12 months. Statistical analyses included linear mixed effects and generalized equation estimation models. RESULTS: Fenestration had no significant impact on tendon thickness (p = 0.46). Conversely, surgery significantly increased tendon thickness at 6 months (p < 0.0001) and remained elevated at 12 months (p = 0.04). Tendon echostructure exhibited a group effect (p = 0.03), indicating a higher proportion of pathological scores in the surgery group post-intervention compared to the fenestration group. Both groups showed a similar reduction in neovascularity from 6 to 12 months postintervention (p = 0.006). Shear-wave velocity increased in the fenestration group at 6 months (p = 0.04), while the surgery group experienced a nonsignificant decrease at 6 months, with some improvement at 12 months (p = 0.08). Changes in shear-wave velocity did not correlate with clinical outcome. CONCLUSIONS: Fenestration and surgery reduced tendon neovascularity over time. Unlike surgery, fenestration did not impact tendon size while improving tendon echostructure and elasticity. CRITICAL RELEVANCE STATEMENT: Fenestration and surgery equally alleviated symptoms and decreased tendon neovascularity in lateral elbow tendinopathy; however, fenestration did not alter tendon thickness and improved echostructure and shear-wave velocity, suggesting shear-wave velocity's potential for quantitatively monitoring tendon elasticity during healing. KEY POINTS: Reliable markers for monitoring healing response and informing treatment protocols in elbow tendinopathy are lacking. Fenestration and surgery reduced tendon neovascularity, while fenestration improved tendon echostructure and shear-wave velocity. Shear-wave velocity may provide quantitative measures to monitor tendon elasticity in response to treatment.

18.
Mech Syst Signal Process ; 2142024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38737197

RESUMO

Laser Doppler vibrometry and wavefield analysis have recently shown great potential for nondestructive evaluation, structural health monitoring, and studying wave physics. However, there are limited studies on these approaches for viscoelastic soft materials, especially, very few studies on the laser Doppler vibrometer (LDV)-based acquisition of time-space wavefields of dispersive shear waves in viscoelastic materials and the analysis of these wavefields for characterizing shear wave dispersion and evaluating local viscoelastic property distributions. Therefore, this research focuses on developing a piezo stack-LDV system and shear wave time-space wavefield analysis methods for enabling the functions of characterizing the shear wave dispersion and the distributions of local viscoelastic material properties. Our system leverages a piezo stack to generate shear waves in viscoelastic materials and an LDV to acquire time-space wavefields. We introduced space-frequency-wavenumber analysis and least square regression-based dispersion comparison to analyze shear wave time-space wavefields and offer functions including extracting shear wave dispersion relations from wavefields and characterizing the spatial distributions of local wavenumbers and viscoelastic properties (e.g., shear elasticity and viscosity). Proof-of-concept experiments were performed using a synthetic gelatin phantom. The results show that our system can successfully generate shear waves and acquire time-space wavefields. They also prove that our wavefield analysis methods can reveal the shear wave dispersion relation and show the spatial distributions of local wavenumbers and viscoelastic properties. We expect this research to benefit engineering and biomedical research communities and inspire researchers interested in developing shear wave-based technologies for characterizing viscoelastic materials.

19.
J Belg Soc Radiol ; 108(1): 50, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38737378

RESUMO

Teaching point: Cystic artery pseudoaneurysm is a rare condition that should be considered in patients with unexplained abdominal pain, a history of gallbladder disorders, or signs of hemorrhage, and can be diagnosed by Doppler ultrasound.

20.
J Med Life ; 17(1): 116-122, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38737666

RESUMO

Ultrasound can identify important characteristics in primary hypothyroidism and diffuse hyperthyroidism (Graves' disease). Therefore, sonologists are actively investigating ultrasound criteria to differentiate between these two conditions. Nevertheless, practice shows the absence of such ultrasonic landmarks. For the first time in the literature, three cases of primary hypothyroidism have demonstrated an ultrasound pattern identical to that of Graves' disease. This pattern includes the presence of goiter, marked total hypoechogenicity of the parenchyma, significantly or moderately increased blood flow intensity ('thyroid inferno'), and elevated peak systolic velocity of the superior thyroid arteries. These signs are less common in hypothyroidism compared to hyperthyroidism. Diagnostic data suggest that the pathogeneses of primary hypothyroidism and Graves' disease share the same mechanisms, leading to similar thyroid ultrasound patterns. One of these shared mechanisms is presumably thyroid overstimulation by the autonomic nervous system, which is adequate to the body's hormonal requirements in hypothyroidism but excessive in hyperthyroidism.


Assuntos
Doença de Graves , Hipotireoidismo , Glândula Tireoide , Ultrassonografia , Humanos , Doença de Graves/diagnóstico por imagem , Doença de Graves/complicações , Hipotireoidismo/diagnóstico por imagem , Hipotireoidismo/complicações , Ultrassonografia/métodos , Glândula Tireoide/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade , Adulto , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...